Cold treatment or cryogenic or sub-zero treatment

N.B.: The information contained in this sheet comes from reliable sources. Nevertheless, it is provided without any guarantee, express or implied, of its accuracy.


Principle:

Cold treatment (or cryogenic treatment) consists of cooling mechanical parts above ambient temperature after a quenching heat treatment. The holding temperature is between 0°C and -150°C (most often between -80 and -100°C for steels).

Justification of cold treatment on steels.

The need to reach a temperature lower than the ambient temperature supposes that metallurgical transformations can occur for temperatures reached lower than this one. This is the case for some iron-carbon alloys for which the Mf point of the end of the transformation of austenite into martensite is itself lower than 0°C, hence the existence ofresidual austenite (or retained austenite) after quenching.

Mf depends on the carbon content and the chemical composition of the alloying elements.

Mf (°C) = (361 to 461) - 474 (C %) - 33 (Mn %) - 14 (Cr %) - 21 (Mo %)
(Steven and Haynes law) for low alloy steels.

Mf is lower than 0°C as soon as the carbon content is higher than the eutectoid (0.8 % carbon in the absence of alloying elements), hence an increased risk of residual austenite after case hardening.
The existence of residual austenite in the structure is an unstable situation, it will decompose if the temperature is lowered enough to reach the Mf temperature. It can also be transformed under the action of destabilizing conditions: high stresses, vibrations, cyclic efforts.

The austenite will then decompose in an uncontrolled way into martensite (sometimes called secondary martensite) by producing

This martensite is very brittle and can cause volume deformations and risks of local overvoltages which can go as far as cracking. This unaged martensite is also brittle.
Beside martensite, austenite is a constituent of low hardness. Its presence is reflected by soft patches.

Cold treatment will therefore have the effect on steels containing residual austenite:

  • increase the hardness and the elastic limit with a correlative decrease in resilience and an increase in internal stresses,

  • increase the dimensional stability of the parts. It is therefore particularly recommended for gauges and elements with very tight clearances.

It is essential on mechanical components intended to be mounted by press fit, by shrink fitting with liquid nitrogen or working at low temperatures (case of cryogenic components or aeronautical structural parts).

Justification of cold treatment on aluminum alloys
After quenching, aluminum alloys suitable for heat treatment hardening are in their maximum malleable state (fresh quenching state), they will harden by tempering or aging. For parts that need to be deformed or calibrated between hardening and final hardness, the malleable state is maintained by keeping the parts in a cold box to delay the start of the maturation process. This stay will allow the parts to be taken as and when the deformation equipment is available before the maturation process starts.


APPLICATIONS OF COLD TREATMENT


Industrial applications on steels

  • Deformation tools

  • Cutting tools

  • Parts made of extra hard alloyed cast iron

  • Cemented parts

  • Sizes and gauges

  • Precision cutting punches

  • Aeronautical parts

Precautions for implementation

Immersion in a very low temperature environment constitutes a thermal shock that can lead to the risk of tapping. This is why a stress relieving tempering at low temperature (125°C for example) can be recommended in order to reduce the brittleness of the martensite which will be exposed to the cold and to the stresses of the secondary martensite formation, even if it can stabilize the residual austenite. Immersion in an air-cooled chamber is preferred to immersion in a cold liquid such as liquid nitrogen or nitrogen-alcohol mixtures.
After the cold treatment, the austenite previously retained is completely transformed into fresh martensite which must be quickly subjected to stress relieving tempering in order to avoid the risks of delayed tapping.

Material used

  • Isothermal liquid nitrogen chamber

  • Compressor cooled cabinet (temperature limit - 100°C)

  • Refrigerated cabinet with liquid nitrogen circulation coil (nitrogen flow regulates the temperature)

Some of these boxes are equipped with a heating system to bring the rooms to a temperature higher than the ambient temperature.

Types of materials suitable for the application

  • Steels X 100 Cr Mo 17, X 200 Cr 12, 90 Mn Cr W 5

  • High speed and semi high speed steels

  • Cemented steels: 16 Ni Cr 12, 16 Cr Ni Mo 13, 20 Ni Mo 14, 16 Cr Mn 6, etc.

  • Bearing steel type 100 Cr 6

Application examples of typical ranges

Threaded gauge material X 200 Cr 12

  • Overall draft

  • Finishing and threading with grinding reserve

  • Tempering

  • Tempering 180°C

  • Passage to cold - 80°C

  • Tempering 180°C

  • Rectification

Aeronautical part X 100 CrMo 17

  • Rough machining

  • Stabilization

  • Machining and finishing

  • Passage to cold - 80°C

  • Tempering 160°C

  • Passage to cold - 80°C

  • Tempering 160°C

  • Passage to cold - 80°C

  • Tempering 160°C

Application on aluminum alloys

Example: on a 7075 alloy part after fresh quenching, inter-operation holding in a cold chamber at -23°C, ability to bring back from ambient temperature to -23°C in less than 15min, without exceeding -18°C in the chamber.


Implementation


Main equipment (furnace, reactor, line, machine...)

Energy and fluids (gases, chemicals, quenching liquids, salts...)

If you are a company interested in being listed on this page, please contact us: a3ts@a3ts.org


Read more


Joseph Membré

Passionate about beautiful brands and branding, I fell in love with webdesign in 2012. Since then, I've been helping my clients create their brand, and their online presence. A fervent supporter of Squarespace and Shopify - I help spread the word about these platforms that have clearly changed the game in the world of webdesign. Always on the lookout, I'm constantly learning about the latest web tools and trends to stay on top of things.

http://www.square-design.fr
Previous
Previous

Vacuum heat treatments

Next
Next

Globulization annealing of structural steels